TIA/EIA-568-C.2: Category 6 System Channel

TIA/EIA-568-C.2: Category 6 System Channel

TIA EIA 568 C.2Category6SystemChannel

Frequency
MHz

Insertion Loss
dB/100M(Max)

NEXT
dB(Min)

PS NEXT
dB(Min)

ELFEXT
dB(Min)

PS ELFEXT
dB(Min)

Return Loss
dB(Min)

1

2.1

65.0

62.0

63.3

60.3

19.0

4

4.0

63.0

60.5

51.2

48.2

19.0

8

5.7

58.2

55.6

45.2

42.2

19.0

10

6.3

56.6

54.0

43.3

40.3

19.0

16

8.0

53.2

50.6

39.2

36.3

18.0

20

9.0

51.6

49.0

37.2

34.2

17.5

25

10.1

50.0

47.3

35.3

32.3

17.0

31.25

11.4

48.4

45.7

33.4

30.4

16.5

62.5

16.5

43.4

40.6

27.3

24.3

14.0

100

21.3

39.9

37.1

23.3

20.3

12.0

200

31.5

34.8

31.9

17.2

14.2

9.0

250

35.9

33.1

30.2

15.3

12.3

8.0

TIA/EIA-568-C.2: Category 6 System

 

Frequency
MHz

Insertion Loss
dB/90M(Max)

NEXT
dB(Min)

PS NEXT
dB(Min)

ELFEXT
dB(Min)

PS ELFEXT
dB(Min)

Return Loss
dB(Min)

1

1.9

65.0

62.0

64.2

61.2

19.1

4

3.5

64.1

61.8

52.1

49.1

21.0

8

5.0

59.4

57.0

46.1

43.1

21.0

10

5.5

57.8

55.5

44.2

41.2

21.0

16

7.0

54.6

52.2

40.1

37.1

20.0

20

7.9

53.1

50.7

38.2

35.2

19.5

25

8.9

51.5

49.1

36.2

33.2

19.0

31.25

10.0

50.0

47.5

34.3

31.3

18.5

62.5

14.4

45.1

42.7

28.3

25.3

16.0

100

18.6

41.8

39.3

24.2

21.2

14.0

200

27.4

36.9

34.3

18.2

15.2

11.0

250

31.1

35.3

32.7

16.2

13.2

10.0

The Advantage of Albertsons Cat6 System

  • The guarantee value of the performance surpass the standard of ISO/IEC 11801:2002, IEC61156-5, TIA/EIA 568-C, EN50173, and other standards of Cat6/ ClassE, the transmission speed is up to 550MHz.
  • Colorfull cross identify the type of cables quickly in the construduciton and supply the conveniently management, meet the standard of TIA/EIA-606.
  • Supports up to 4 connections for any length of the link, up to 100 meters.
  • System channel optimization design, maximum bandwidth and SNR margin for mission-critical transmission.
  • Full support for IEEE 802.3 10GBASE-T / 1000BASE-T, TIA-854-A 1000BASE-TX, ATM Forum CB1G and other traditional network applications (including video applications and BAS systems).
  • Downwards compatible with Cat6 Class / Class E or lower Albertsons other copper systems.

Main products of Albertsons Cat6 System:

  • 4 pair unshield / shield twisted cable
  • 19 inch 24 ports Easy patch panel
  • 19 inchi 24 ports keystone metal blank patch panel
  • Cat6 keystone (unshield / shield)
  • Cat6 soft patch cord (unshield / shield)

2.Category 6 cable

2.1 Category 6 unshield cable

Cat6 UTP Cable

  • Product Description

Albertsons cat6 cables determine a new performance evaluation indicators, surpassing the requirment of the ANSI / TIA / EIA-568-C.2 of the category 6. When it used as a horizontal cabling in the six systems in United States, it provides a significant margin space, with the Albertson's high-performance Cat6 connection hardware, it could provide more optimized transmission performance supporting.

  • Product Characteristics
  • Passing the bandwidth testing requirements of TIA / EIA-568-C.2 Category 6 250MHZ.
  • Cross separates the pair wire and maintains a stable position of the pair cable, reducing the near-end crosstalk loss (NEXT) and maintaining impedance stability.
  • Colorfull cross identify the type of cables quckily in the construduciton and supply the conveniently management, meet the standard of TIA/EIA-606.
  • With the accurate twist pitch and balanced design, the cable will reduce the near-end crosstalk loss (NEXT).
  • Passing the strict testing requirments of the four connecting points channel, the every performance index are higher than the international, North American, European standards(such as: ISO/IEC 11801: 202, IEC61156-5, TIA/EIA 568-C.2, EN50173, EN50288).
  • The maximum bandwidth and SNR margin are used for mission-critical transmission.
  • Providing a variety of fire rating cable, high flame retardant low smoke halogen-free cable and different color sheath, it meet different user needs.
  • Providing 1 ~ 305m cable length mark, reduce waste.
  • Electrical Characteristics
  • Characteristic impedance: (f:1-250MHz)100±15Ω
  • The maximum unbalancedDC resistance:≤2.5%
  • Working capacitance: 5.6nF/100 meters
  • Unbalanced capacitance:<330pF/100 meters
  • Delay deviation:(max)45ns/100m
  • NVP: 69%
  • Physical characteristics

Conductor

23AWG(0.575mm) / OFC(99.99%)

Insolution

HDPE

HDPE

FEP

LSZHP

Jacket

PVC

PVC

FEP

LSZHP

Flame retardant

CM

CMR

CMP

LSZH

Color

Blue(01), Brown(04), Red(07), Lemon green(03), Orange(02), Gray(05), White(06), Black(08), Yellow(09)

OD

6.5±0.2mm

6.5±0.2mm

6.5±0.2mm

6.5±0.2mm

Operating temprature

-40℃~70℃

Maximum pulling force

210N

Minimum bending radius

Dynamic: 10 times. Static: 4 times

Package

305m or 1000ft/wooden drum, carton package

  • Production standards and specifications
  • ISO/IEC 11801
  • TIA/EIA-568-C.2
  • EN50173
  • UL CM
  • UL CMR and CSA FT4
  • UL CMP and CSA FT6
  • LSZH: IEC 60332-1 & 60332-3, IEC 1034, IEC 754, NES 713
  • Transmission performance:
 

 TIA/EIA&ISO/IEC

   

 ALBERTSONS Typical value

Frequency
(MHz)

Insertion
Loss (dB)

NEXT
(dB)

PS NEXT
(dB)

ACR
(dB)

PSACR
(dB)

ACR-F
(dB)

PSACR-F
(dB)

Return Loss (dB)

Propagation
Decay (ns)

1.0

2.1

2.0

74.3

79.3

72.3

80.3

72.2

82.9

70.2

75.5

67.8

77.8

64.8

73.8

20

25

570

550

4.0

3.8

3.7

65.3

70.3

63.3

71.3

61.4

72.1

59.4

64.8

55.8

65.8

52.8

61.8

23

28

552

532

10.0

6.0

5.8

59.3

64.3

57.3

65.3

53.3

64

51.3

56.7

47.8

57.8

44.8

53.8

25

34

545

550

16.0

7.6

7.4

56.2

61.2

54.2

62.2

48.6

59.4

46.6

52.1

43.7

53.7

40.7

49.7

25

30

543

548

20.0

8.5

8.2

54.8

59.8

52.8

60.8

46.2

57.1

44.2

49.9

41.8

51.8

38.8

47.8

25

30

542

547

31.25

10.8

10.4

51.9

56.9

49.9

57.9

41.1

49.5

39.1

44.9

37.9

44.9

34.9

43.9

23.6

28

540

515

62.5

15.5

15.0

47.4

52.4

45.4

53.4

31.9

40.5

29.9

36

31.8

41.9

28.9

37.9

21.5

28

539

544

100

19.9

19.3

44.3

49.3

42.3

50.3

24.4

33.1

22.4

28.7

27.8

37.8

24.8

33.8

20.1

28

538

543

160

25.8

25.0

41.2

46.2

37.8

46.5

15.5

24.3

13.5

20.1

23.7

33.7

20.7

29.7

18.7

27

537

542

200

29.0

27.9

39.8

44.8

36.3

45.1

10.6

19.8

8.6

16

21.8

31.8

18.8

27.8

18

25

537

542

250

33.0

31.8

38.3

43.3

35.1

43.7

5.3

14.6

3.3

10.8

19.8

30

16.8

25.8

17.3

25

536

541

300.0*

36.6

35.2

37.1

42

34.1

42.6

0.5

9.9

-1.5

6.3

18.3

29

15.3

24

16.8

23

536

541

400.0*

43.0

41.7

35.3

40

33.3

41.2

-7.9

1.4

-9.9

-2.3

15.8

25

12.8

21

15.9

22

536

541

500.0*

48.9

44.4

33.8

40

31.8

39.9

-15.4

-2.7

-17.4

-2.9

13.8

24

10.8

20

15.2

21

536

541

550.0*

51.8

45.8

33.2

38

30.4

39.2

-18.8

-4.3

-20.8

-2.7

13

23

10

20

14.9

20

536

541

“*”Indicates the test values required for overloaded TIA and ISO standards.

  • Application
  • Structured cabling data transmission cable, transmission of digital and voice, data and video signals.
  • Especially suitable for all E-class links and Cat.6 applications:

IEEE802.3(10Base-T 10M Ethernet)

IEEE802.3U(100Base-TX 100M Ethernet)

IEEE802.3ab(1000Base-T 1000M Ethernet)

IEEE802.3an(10GBase-T 10G Ethernet)

IEEE802.5(Token Ring 4/16 Token Ring)

ATM 155Mbit/s or ATM622 or higher

  • Supports all applications designed for Category 6 or lower cabling systems
  • Installation Points
  • Pleasing confirm all the material, specification and types to meet the design requirement before installation
  • All the type cables can’t be inclined, distorted, burred, broke, damaged and damped.
  • The cable should be kept straight normally, no wring, winding, during the cabling installating.
  • The two side of cable should be with stickers, the stickers need to be written clearly and correctly,the stickers should with good qualiy and not eacy to fall off.
  • Cable bending radius should be kept the minimum requirement, and meet the requirement of cable minimum distance.
  • Type

Type

Description

A096

ABS-6 U/UTP, Cat.6, PVC CM, blue jacket, 305 m/ Drum

A096R

ABS-6 U/UTP, Cat.6, PVC CMR, brown jacket, 305 m/ Drum

A096P

ABS-6 U/UTP, Cat.6, PVC CMP,  red jacket, 305 m/ Drum

A096L

ABS-6 U/UTP, Cat.6, LSZH, green jacket, 305 m/ Drum

Note: If you need other color, Pls let us know when you send order.

3. Cat6 FTP shield cable

  • description

Albertsons Cat6  FTP double shield cable can be used on Horizontal Wiring System and Vertical Wiring building system, supporting the Ethernet, ATM,  Multimedia applications, Fully grasp the future application and development of the network, and apply with the needs of the future network. It’s requirement beyond the TIA/EIA-568-C.2 Category 6, supporting the 250MHz bandwidth application.

  • Product property
  • All the transmission datas are beyond the cat6 LAN reference standards of TIA/EIA-568-C.2 and ISO11801, sopprting the highest 250MHz bandwidth.
  • Double contrast longitudinal lapping & direct alimunimu foil shield structure, can defence the outside EMI, can be suitable for all complicated, difficult electromagnetic environment places using.
  • double shield structures can be prevented from electromagnetic radiation,information leakage, improve the information secrect function.
  • Colorful cross is easy to be identified when install the cables, meet the standard of TIA/EIA-606.
  • Overcome the IEEE 802 ethernet all requirement, support Ethernet, ATM, each pair 250Mbps, multimedia application.
  • Afford different kinds of fire grade and LSZH with different jacket color, meet all customers’ requirement.
  • Support 1~305m length meter marking, easy for control and reduce the waste.
  • Electrical characteristics
  • Impedance: (f:1-250MHz)100±15Ω
  • Max direct-current resistance:≤2.7%
  • Working capacity:5.6nF/100米
  • Unbalance capacity:<330pF/100米
  • NVP: 69%
  • Physical characteristics

conductor diameter/Material

23AWG(0.575mm) /OFC 99.99%

insulation material

HDPE

HDPE

FEP

LSZHP

Jacket material

 (PVC)

 (PVC)

 (FEP)

(LSZHP)

Fire rating

CM

CMR

CMP

LSZH

Jacket color

blue(01), brown(04), red(07), green (03), orange(02),

grey(05), white(06), black(08), yellow(09)

Cable diameter

7.0±0.2mm

7.2±0.2mm

7.2±0.2mm

7.2±0.2mm

Working temperature

-40℃~70℃

max pull length

210N

Min bending radius

dynamic:10 times of cable OD, static:8times of cable OD

Standard packing

305m/drum(1000ft), box package

           
  • Production standard
  • ISO/IEC 11801
  • TIA/EIA-568-C.2
  • EN50173
  • UL CM
  • UL CMR and CSA FT4
  • UL CMP and CSA FT6
  • LSZH: IEC 60332-1&60332-3, IEC 1034, IEC 754, NES 713
  • Transfer chracteristic:
 

 TIA/EIA&ISO/IEC

   

 ALBERTSONS type value

Frequency
(MHz)

Insertion
Loss(dB)

NEXT
(dB)

PS NEXT
(dB)

ACR
(dB)

PSACR
(dB)

ACR-F
(dB)

PSACR-F
(dB)

Return oss(dB)

Propagation
Decay(ns)

1.0

2.1

2.0

74.3

79.3

72.3

80.3

72.2

82.9

70.2

75.5

67.8

77.8

64.8

73.8

20

25

570

550

4.0

3.8

3.7

65.3

70.3

63.3

71.3

61.4

72.1

59.4

64.8

55.8

65.8

52.8

61.8

23

28

552

532

10.0

6.0

5.8

59.3

64.3

57.3

65.3

53.3

64

51.3

56.7

47.8

57.8

44.8

53.8

25

34

545

550

16.0

7.6

7.4

56.2

61.2

54.2

62.2

48.6

59.4

46.6

52.1

43.7

53.7

40.7

49.7

25

30

543

548

20.0

8.5

8.2

54.8

59.8

52.8

60.8

46.2

57.1

44.2

49.9

41.8

51.8

38.8

47.8

25

30

542

547

31.25

10.8

10.4

51.9

56.9

49.9

57.9

41.1

49.5

39.1

44.9

37.9

44.9

34.9

43.9

23.6

28

540

515

62.5

15.5

15.0

47.4

52.4

45.4

53.4

31.9

40.5

29.9

36

31.8

41.9

28.9

37.9

21.5

28

539

544

100

19.9

19.3

44.3

49.3

42.3

50.3

24.4

33.1

22.4

28.7

27.8

37.8

24.8

33.8

20.1

28

538

543

160

25.8

25.0

41.2

46.2

37.8

46.5

15.5

24.3

13.5

20.1

23.7

33.7

20.7

29.7

18.7

27

537

542

200

29.0

27.9

39.8

44.8

36.3

45.1

10.6

19.8

8.6

16

21.8

31.8

18.8

27.8

18

25

537

542

250

33.0

31.8

38.3

43.3

35.1

43.7

5.3

14.6

3.3

10.8

19.8

30

16.8

25.8

17.3

25

536

541

300.0*

36.6

35.2

37.1

42

34.1

42.6

0.5

9.9

-1.5

6.3

18.3

29

15.3

24

16.8

23

536

541

400.0*

43.0

41.7

35.3

40

33.3

41.2

-7.9

1.4

-9.9

-2.3

15.8

25

12.8

21

15.9

22

536

541

500.0*

48.9

44.4

33.8

40

31.8

39.9

-15.4

-2.7

-17.4

-2.9

13.8

24

10.8

20

15.2

21

536

541

550.0*

51.8

45.8

33.2

38

30.4

39.2

-18.8

-4.3

-20.8

-2.7

13

23

10

20

14.9

20

536

541

“*”is for Overload TIA and ISO standard requirement test data.

  • application
  • Struacturing data transfer cable, transfer the digit and sound, data, and video.
  • Complicated electromagnetic environment, strong interference places ( such as radar station, large power distribution room, hospital radiation department, large factory and so on).
  • Strictly secret institutions( such as government, administration of politics and law institution, police, armed police, border defence, arm and other institutions).
  • suitable for all E grade permanent link and Cat.6 application

IEEE802.3(10Base-T 10M Ethernet)

IEEE802.3U(100Base-TX 100M Ethernet)

IEEE802.3ab(1000Base-T 1000M Ethernet)

IEEE802.3an(10GBase-T 10G Ethernet)

ATM 155Mbit/s  or ATM62 or higher

  • Support all Cat.6 or lower cabling installation system design application.
  • installation note:
  • Confirming all the material, specification and types meet the design requirement  before installation.
  • All the type cables can not be inclined, distorted, burred, broke, damaged and damped.
  • The cable should be kept straight normally, no wring, winding, during the cabling process.
  • The cable’ends should be with stickers,the stickers need  to be written clearly and correct, stickers with good performance and fixed well on the cable.
  • Cable bending radius should be kept the minimum requirement, and meet the requirement of cable minimum distance.
  • Type

n  type

description

A096F

ABS-6 F/UTP, Cat.6, PVC CM, blue, 305 m/ drum

A096RF

ABS-6 F/UTP, Cat.6, PVC CMR, brown,305 m/ drum

A096PF

ABS-6 F/UTP, Cat.6, PVC CMP, red, 305 m/ drum

A096LF

ABS-6 F/UTP, Cat.6, LSZH, green, 305 m/ drum

A096F2

ABS-6 F²/UTP, Cat.6, PVC CM, blue, 305 m/ drum

A096RF2

ABS-6 F²/UTP, Cat.6, PVC CMR, brown, 305 m/ drum

A096PF2

ABS-6 F²/UTP, Cat.6, PVC CMP, red, 305 m/ drum

A096LF2

ABS-6 F²/UTP, Cat.6, LSZH, green, 305 m/ drum

Note: If you need other color, Pls let us know when you send order.

2.2 CAT6 KEYSTONE

2.2.1CAT6 UTP Keystone

        

          Cat6 180degree                 Cat6 180 degree free installation

Cat6 180 degree bonding type

with the lock of patch cord

  • Product description

    Adopt the technology of innovated structural style and original creation  impedance banlance, high performance print circuits, With special-shaped lily design, to achieve crosstalk cancellation function, so that the information module can eliminate all kinds of high-frequency crosstalk. Compliant with IEEE802.3ab specification for 10G high-speed LAN applications, providing sufficient bandwidth margin for future applications.

  • Product features
  • Transmission performance parameters meet ISO / IEC 11801 and TIA / EIA 568-C.2 standards.
  • Through the lance, terminals and printed circuit continuous impedance analysis, to achieve the best impedance matching relationship.
  • lint 50μi overall gold, to prevent surface oxidation, improve contact performance, to ensure performance and service life.
  • Shaped pins can not only make the crystal head contact is not in a plane, so as to ensure the best near-end crosstalk, but also to ensure that more than 1500 times the plug.
  • back line block spire structure design, so that the twisted pair of twisted and separate core line easier, faster construction.
  • IDC end reed, high quality phosphor bronze, the overall nickel plating, to ensure that the number of termination over 300 times.
  • special oblique 45 degrees IDC design, four directions, can isolate the relative position of each line pair, keep the line from the twist distance, so that the performance after the construction more stable, more durable termination, construction easier.
  • support the mainstream of the 110 termination, to ensure the connectivity of the versatility and reliability of the connection
  • Transparent protective cover to prevent dust and keep the cable card firmly, to reduce the cable bending stress deformation on the transmission performance of the impact.
  • free cable installation module, termination protection cover anti-anti-plug design, effectively improve the efficiency of the end
  • The use of high-quality flame-retardant polycarbonate material, in line with UL94V-0 fire protection requirements.
  • 90 degrees, 180 degrees cable way, free cable installation and other three modules and a variety of colors to choose from.
  • Compatible with all Aberdeen series of panels and 19-inch empty rack.
  • Electrical characteristics
  • DC Resistance:≤300mΩ
  • Contact resistance:≤20mΩ
  • Compressive strength 1000V(AC750V) 1min No breakdown and arcing
  • Insulation resistance≥1000MΩ
  • Physical characteristics
  • lily: phosphor bronze, the whole 50μi gold-plated
  • IDC terminal: phosphor bronze, the overall nickel plating, card access 22-26AWG conductor
  • The number of times the plug and socket are engaged≥1500
  • Number of wire termination≥300
  • Information Module Body: Flame Retardant Polycarbonate UL 94V-0, White, Red, Black, Green, Blue
  • Protective cover: flame retardant polycarbonate UL 94V-0
  • Operating temperature: -40℃~70℃
  • Production standards and specifications
  • ISO/IEC 11801
  • TIA/EIA-568-C.2
  • EN50173
  • UL 94V-0
  • FCC 68 sectional specifcation and IEC 60603-7
  • Application
  • Applicable to all Cat6 or E channel applications.
  • Suitable for work area, inter-office / inter-device subsystem and data center applications.
  • installation tips:
  • Before termination, please press the information on the model T568A or T568B color code to indicate the placement of the core sequence.
  • use the United States Ai Berson wire tools or high-quality general-purpose 110 cable tool termination core.
  • After the termination of the protective cover, in order to ease the tension for the line.
  • Free cable information module before installation, confirm the core line by the end of the hat on the standard order, the correct and secure access to the main information module, remove the excess core.
  • For details, please refer to the instruction manual.
  • PACKING:
  • Plastic bags/ PCS
  • Product style:

model

Product description

AK6-06

ABS-6 Cat.6 keystone Module, White, UTP, 180DEGREE

AK6-006

ABS-6 Cat.6 keystone Module, White, FREE Installtion FTP 180DEGREE

AK63-0906

ABS-6 Cat.6 keystone Module, White, UTP, 90DEGREE, WITH LOCK

2.2.2 CAT6 FTP Keystone

Cat6 180 Degree free installtion

  • Product description

American Albertsons cat6 FTP keystone with excellent crosstalk cancellation technology,in the parameter of NEXT and PSNEXT , With its superior indicators, to ensure a very high network transmission capacity. It is suitable for high-density and high-speed local area network. It provides sufficient bandwidth increment for the future use of high security units such as political law, security and military units.

  • Product features
  • Transmission performance parameters meet ISO / IEC 11801 and TIA / EIA 568-C.2 standards.
  • The main body with full nickel-plated metal casting shell, fully shielded design to optimize the shielding effect, effectively prevent EMI.
  • Through the lance, terminals and printed circuit continuous impedance analysis, to achieve the best impedance matching relationship.
  • lint 50μi overall gold, to prevent surface oxidation, improve contact performance, to ensure performance and service life.
  • Terminate the protective cover to prevent dust and keep the cable card firmly, to reduce the cable bending stress deformation on the transmission performance, while making the performance after the construction more stable, more durable termination, construction easier.
  • The use of high-quality flame-retardant polycarbonate material, in line with UL94V-0 fire protection requirements.
  • Compatible with all Aberdeen 19-inch series of black patch panels.
  • Electrical characteristics
  • DC Resistance:≤300mΩ
  • Contact resistance:≤20mΩ
  • Compressive strength 1000V(AC750V) 1min No breakdown and arcing
  • Insulation resistance≥1000MΩ
  • Physical characteristics
  • Lily: phosphor bronze, the whole 50μi gold-plated
  • IDC terminal: phosphor bronze, card access 22-26AWG conductor
  • Shielded enclosure: 360 degree fully nickel plated metal castings
  • Plug and socket the number of joints ≥ 1500
  • wire termination number ≥ 300
  • Information Module Body: Flame Retardant Polycarbonate UL 94V-0, White, Red, Black, Green, Blue
  • protective cover: flame retardant polycarbonate UL 94V-0
  • Operating temperature: -40℃~70℃
  • Production standards and specifications
  • ISO/IEC 11801
  • TIA/EIA-568-C.2
  • EN50173
  • UL 94V-0
  • FCC 68 sectional specification and IEC 60603-7
  • Application
  • Suitable for all Cat6 or E channel applications.
  • Transmit digital and simulate voice data and video signals over the network.
  • Electromagnetic environment complex, strong interference areas (such as: radar stations, large distribution room, hospital radiology room, large factories and field ore, etc.).
  • High security departments (such as government agencies, political and administrative agencies, public security, armed police, border, military and other organs need high security).
  • Installation Notes:
  • Place the wires according to T568A or T568B color code shown on the keystone jack before connecting the termination.
  • Use US Albertsons’ Crimping tool or high quality general 110 Crimping tool to connect the core wires.
  • Snap on the protective cover to relieve tension on the twisted pairs after connected.
  • Before fixing the tool free keystone jack, make sure the wires placed by the color code shown on the top cap, properly and securely snap into the keystone jack, then remove the redundant core wires.
  • Finally close the shielded shell, fasten it into the shielded keystone jack firmly.
  • Details please refer to the Operating instructions.
  • Packaging
  • 1PC/PE BAG
  • Product Model

Model

Description

AK6S-006

      ABS-6 Cat.6 keystone Jack, White, Tool Free, Shielded, 180°

2.3 Cat6 Patch Panel

2.3.1 Cat6 Unshielded Patch Panel

Cat6 UTP 24 Port Easy Connected Patch Panel

19 inch 24 Port Angled Hollow Patch Panel

  • Product Description

US Albertsons’ cat6 patch panel is used for cat6 wiring between the equipment or wiring closet, to achieve trunk distribution and network or terminal equipment connection. Connect horizontal or vertical cable through the back of the IDC termination reed, to provide high-speed LAN data transmission services.

  • Product Features
  • Overall 50μi gold-plated, insulation displacement gas-tight card technology, contact never oxidation.
  • Color code instruction printable and changeable, compliance with TIA/EIA-606, make termination management clearer and simpler.
  • Permanent logo on the keystone connector on the two sides of Patch Panel to make construction and maintenance management convenient.
  • 19 inch angled hollow patch panel can save the cabinet units & protect the customer's investment.
  • All metal frame structure to ensure the product of higher mechanical strength and reliability.
  • Enough label space to make the keystone management clearer and easier.
  • Back Cable Bracket to control the bending radius of the cable & provide a proper cable management, make sure vertical cable direction, which make the system more stable after construction and the cable array more clearer and pleasing.
  • 24 port 1U easy connected patch panel, compatible with T568A and T568B wires connected ways.
  • 24 port hollow patch panel compatible all US Albertsons’ keystone jack, make sure all keystone jack of working areas and wiring closet uniform, which make construction management and post-maintenance easily.
  • Standard 19”installment, applicable to a wide range, with simple and quick installation, maintenance, and expansion.
  • Electrical Features
  • Direct Current Resistance: ≤300mΩ
  • Contact Resistance: ≤20mΩ
  • Dielectric Strength 1000V(AC750V) 1min no breakdown and arcing
  • Insulation Resistance≥ 1000MΩ
  • Physical Features
  • Gold Pin: phosphor bronze, overall plating gold 50μi.
  • IDC terminal: phosphor bronze, overall nickel plating, access 22-26AWG conductor.
  • The number of joints between plug and socket≥ 1500.
  • The number of wire termination ≥ 300.
  • Cable Management Bracket: Sprayed steel + flame retardant polycarbonate UL 94V-0.
  • Metal Patch Panel: Cold-Roll steel sheet, powder coated finish, black sanding texture.
  • Plastic Part: High impact strength material, UL 94V-0 Flame Class.
  • Operating Temperature:-40℃~70℃
  • Production Standard
  • ISO/IEC 11801
  • TIA/EIA-568-C.2-1
  • EN50173
  • UL 94V-0
  • Applications
  • Transmit digital and simulate voice data and video signals over the network.
  • Suitable for centralized point interoperability, management, equipment subsystem applications.
  • Suitable for all E channel and Cat6 applications.

IEEE802.3(10Base-T 10M Ethernet)

IEEE802.3U(100Base-TX 100M Ethernet)

IEEE802.3ab(1000Base-T 1000M Ethernet)

IEEE802.3an(10GBase-T 10G Ethernet)

IEEE802.5(Token Ring 4/16)

ATM 155Mbit/s or ATM622 or Advanced

  • Supports all applications designed for Category 6 or lower cabling systems.
  • Installation Notes:
  • Place the wires according to T568A or T568B color code shown on the keystone jack before connecting the termination.
  • Use US Albertsons’ Crimping tool or high quality general 110 Crimping tool to connect the core wires.
  • Details please refer to the Operating instructions.
  • Packaging
  • Each Patch Panel in a carton (with user identification, cable ties, cable management, mounting screws, operating instructions, etc.).
  • Product Model:

Model

Production Description

AHD624

ABS-6 1HU Cat.6 Patch Panel,24 RJ45,Unshielded,

AHD024-ANG

1HU 24 port, Unshielded General Hallow Patch Panel, Folded Angled, with cable bracket

2.3.2 Cat6 Shielded Patch Panel

Cat6 FTP 24 Port Patch Panel

   19’ 24 Port Metal Bracket

  • Product Description

US Albertsons’ metal patch panel, the metal frame has a shield grounding terminal and wire, cable shield grounding card design, not only the cable shield is reliably grounded, but also relieve the cable tension, keep the line to the end of the contact point.

  • Product Features

The distribution frame integrated management of the cable structure, to provide a reasonable cable routing management, relieving tension,

  • EN50173
  • UL 94V-0
  • application
  • transmit digital and analog voice, data and video signals over the network.
  • Applicable to all Cat6 or E channel applications.
  • Suitable for management, inter-equipment subsystem applications.
  • electromagnetic environment complex, strong interference places (such as: radar stations, large distribution room, hospital radiology, large factories and field ore, etc.).
  • high security units (such as government agencies, political and administrative, public security, armed police, border, military and other confidential units).
  • Installation tips:
  • Open the shielded cable, remove the jacket and retain a shield and drain line, the shield layer after the reverse wrapped in the jacket, and the drainage line wrapped around the shield, and then fixed to the ground Device, the formation of a complete, continuous effective shielding.
  • Before termination, please follow the module rear T568A or T568B color code sequence placed a good core.
  • use the United States Aibo Sen line tools or high-quality general-purpose 110-line tool terminal core.
  • Make sure all core termination is completed, properly cover the cover and secure it.
  • Install the patch panel wiring securely in the rack.
  • For details, please refer to the instruction manual for each pack.
  • Packing:
  • box with a set of patch panels and accessories (straps, mounting screws, brochures, etc.).
  • Product Type:

Model

Product description

AHD024S

1HU 24-port unshielded / shielded universal all-metal air patch panel with cable tray and ground conductor

AHD624S

ABS-6 1HU Cat.6 patch panel, 24 RJ45, shield,

2.4 Cat6 patch cord

2.4.1 Unshielded / shielded patch for Cat6

   

Cat6 U/UTP & F/UTP Patch Cord 

  • Product Description

The US Albertson high quality Ca6 patch cords meet the TIA / EIA 568-C.2 6 type transmission performance requirements. They provide a high and stable data transmission network for the customer's six types of channels to provide excellent connection hardware, will apply to different wiring environment. All American Aberson Class VI jumpers are 100% rigorously tested to maintain high quality quality.

  • Product characteristics
  • Transmission performance parameters meet the newly issued ISO / IEC 11801 and TIA / EIA 568-C.2 standards.
  • RJ45 plug with soft tail structure, to ensure that the cable and the connection between the crystal head.
  • Crystal head crimp reed 50μinch overall gold-plated, to ensure excellent performance.
  • multi-stranded stranded cable, jumper flexibility is good, easy to bend easily broken.
  • Gradual type of the principle of the extended sheath, anti-skid tensile, to ensure a certain bending radius.
  • provide 1, 2, 3, 5 meters and other lengths and a variety of colors and different fire rating jacket selection.
  • Physical characteristics

CABLE

Conductor diameter / material

Stranded 24AWG / oxygen-free round copper (purity 99.99%)

Insulation material

HDPE

HDPE

FEP

LSZHP

   Jacket     material

Polyvinyl chloride(PVC)

Polyvinyl chloride(PVC)

Fluorinated ethylene propylene(FEP)

Low smoke zero halogen and high flame retardant polyolefin(LSZHP)

Fire-proof level

CM

CMR

CMP

LSZH

Jacket   color

Blue(BL), brown(BR), red(RE), green(GR)、orrange(OR),

Gray(GY), white(WH), black(BA), yellow(YL)

Plug

The transparent polycarbonate meets the UL 94V-0 material

Reed

Material Phosphor Bronze 50 microinches Gold Plating

The number of plugs of the plug

≥1500 times

Pulling force test

≤210N

Minimum bending radius

≥ 21mm (dynamic: 10 times the cable diameter, static: 4 times the cable diameter)

             
  • Production standard and regulations
  • ISO/IEC 11801
  • TIA/EIA-568-C.2
  • EN50173
  • UL 94V-0
  • FCC 68 part of specification and IEC 60603-7
  • UL CM
  • UL CMR and CSA FT4
  • UL CMP and CSA FT6
  • LSZH: IEC 60332-3 & 60332-1,IEC 1034,IEC 754,NES 713
  • Application
  • transmit digital and analog voice, data and video signals over the network.
  • Applicable to work area, centralized point, management room, equipment sub-system jumper application.
  • Suitable for demanding Gigabit Ethernet and some important occasions.

AC

6A

L

UF

-

30

F

03

       
                       
                       
               

color:01-blue;02-orrange;03-green;04-brown;05-grey;06-white;07-red;08-black;09-arrange

           

length:03-1m;05-1.5m;06-2m;09-3m;15-5m;30-10m

 
       

construction:non-U/UTP;F-F/UTP;F2-FF/UTP;F3-F/FTP;SF3-SF/FTP;UF-U/FTP

     

jacket:non-PVC CM;R-PVC CMR;P-PVC CMP;L-LSZH

   
   

type:6A-Cat.6A;6-Cat.6;5E-Cat.5e

     
  • Product model:

model

Item description

AC6-03F01

ABS-6 Cat.6 U/UTP unshielded patch cord PVC CM fire-proof 1meter  blue

AC6-06F01

ABS-6 Cat.6 U/UTP  unshielded patch cord PVC CM fire-proof 2meter  blue

AC6-09F01

ABS-6 Cat.6 U/UTP unshielded patch cord PVC CM fire-proof 3meter  blue

AC6-15F01

ABS-6 Cat.6 U/UTP unshielded patch cord PVC CM fire-proof level 5meter  blue

AC6R-03F04

ABS-6 Cat.6 U/UTP unshielded patch cord PVC CMR fire-proof level 1 meter brown

AC6R-06F04

ABS-6 Cat.6 U/UTP  unshielded patch cord PVC CMR fire-proof level 2 meter brown

AC6R-09F04

ABS-6 Cat.6 U/UTP  unshielded patch cord PVC CMR fire-proof level 3 meter brown

AC6P-03F07

ABS-6 Cat.6 U/UTP unshielded patch cord PVC CMP fire-proof level 1meter red

AC6P-06F07

ABS-6 Cat.6 U/UTP  unshielded patch cord PVC CMP fire-proof level  2meter red

AC6P-09F07

ABS-6 Cat.6 U/UTP  unshielded patch cord PVC CMP fire-proof level 3meter red

AC6L-03F03

ABS-6 Cat.6 U/UTP unshielded patch cord LSZHHigh flame retardant low smoke zero halogen 1 m  green

AC6L-06F03

unshielded patch cord LSZHHigh flame retardant low smoke zero halogen 2 m  green

AC6L-09F03

ABS-6 Cat.6 U/UTP unshielded patch cord LSZHHigh flame retardant low smoke zero halogen 3 m  green

AC6L-15F03

ABS-6 Cat.6 U/UTP unshielded patch cord LSZHHigh flame retardant low smoke zero halogen 5 m  green

AC6F-03F01

ABS-6 Cat.6 FTP  unshielded patch cord PVC CM fire-proof level 1m blue

AC6F-06F01

ABS-6 Cat.6 F/UTP unshielded patch cord PVC CM fire-proof level 2m blue

AC6F-09F01

ABS-6 Cat.6 F/UTP unshielded patch cord PVC CM fire-proof level 3m blue

AC6F-15F01

ABS-6 Cat.6 F/UTP unshielded patch cord PVC CM fire-proof level 5m blue

AC6RF-03F04

ABS-6 Cat.6 F/UTP shielded patch cord PVC CMR fire-proof level 1m brown

AC6RF-06F04

ABS-6 Cat.6 F/UTP shielded patch cord PVC CMR fire-proof level 2m brown

AC6RF-09F04

ABS-6 Cat.6 F/UTP shielded patch cord PVC CMR fire-proof level 3m brown

AC6PF-03F07

ABS-6 Cat.6 F/UTP  shielded patch cord  PVC CMP fire-proof level 1m red

AC6PF-06F07

ABS-6 Cat.6 F/UTP  shielded patch cord  PVC CMP fire-proof level 2m red

AC6PF-09F07

ABS-6 Cat.6 F/UTP  shielded patch cord  PVC CMP fire-proof level 3m red

AC6FL-03F03

ABS-6 Cat.6 F/UTP shielded patch cord LSZH High flame retardant low smoke zero halogen 1 m green

AC6FL-06F03

ABS-6 Cat.6 F/UTP shielded patch cord LSZH High flame retardant low smoke zero halogen 2 m green

AC6FL-09F03

ABS-6 Cat.6 F/UTP shielded patch cord LSZH High flame retardant low smoke zero halogen 3 m green

AC6FL-15F03

ABS-6 Cat.6 F/UTP shielded patch cord LSZH High flame retardant low smoke zero halogen 5 m green

Note: If you need other colors and lengths,  please specify when ordering.

This email address is being protected from spambots. You need JavaScript enabled to view it.

Albertson Company (USA) 2008 was established in Delaware, USA. As a comprehensive company, Albertson Company (USA) invests in global economic hotspots. The investment direction mainly covers three major sectors: communication technology, mining and finance. At present, the main investment targets of the Albertson Company (USA) are South Africa, Chile, China and other countries and regions.